Furthermore, JPB Système’s Lockwire Anti-rotational Devices have been industry proven and in service for over 10 years...
Here is an abstract of testing process:
|
|
SHACKING TABLE TEST:
Sinus test 3Hz to 4000Hz
Level 1G to 100g cc
Sweep : 2oct /min
|
On the right: a classic plug (without JPB Système’s Lockwire Anti-rotational Device) torqued by hand.
|
|
On the left: a JPB Système’s Lockwire Anti-rotational Device NOT torqued, Locking Tabs just engaged (WORST CONDITION).
|
|
RESULTS:
Vibration Loosening of classic Bolts after 1Hour of testing.
IMPOSSIBLE to loose the JPB Système’s under Vibration (test duration: 48H)
|
|
|
|
|
Abstract of ELS and ELS Light shacking table test. Simulation of Fan Blade Off event (FBO). Test under presure : 5080 psi -350 Bar
|
Test of Self-Locking. The plug will automatically lock on the 2nd turn if the first one failed.
|
|
|
This is the most critical frequency. We run the shacking table at 525Hz with acceleration 50g cc.
Note: The resonance phenomenon is visible with the stroboscope light.
RESULT: More that 3 million of cycles passed with success.
|
|
Endurance test: resonance frequency of the spring.
|
|
|